Skip header and navigation

4 records – page 1 of 1.

Acoustic performance of wood-frame buildings

https://library.fpinnovations.ca/en/permalink/fpipub42306
Author
Hu, Lin J.
Date
March 2005
Material Type
Research report
Field
Sustainable Construction
Author
Hu, Lin J.
Contributor
Canada. Canadian Forest Service
Date
March 2005
Material Type
Research report
Physical Description
44 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Acoustic
Series Number
Canadian Forest Service No. 3
Location
Sainte-Foy, Québec
Language
English
Abstract
Commercial and multi-family residential construction represents a growth area for the Canadian wood products industry. To capitalize on this opportunity, a thorough understanding of the necessary products and system attributes will be essential. Adequate levels of noise/sound control in multi-family buildings are mandatory requirements of building codes in Canada, the United States, Europe, and most developed Asian countries. In many jurisdictions, these requirements are as strictly enforced as those for structural sufficiency and fire safety. Much effort has been spent on evaluation of sound transmission class (STC) and impact sound insulation class (IIC) of floor and wall assemblies and on studies of flanking transmission in multi-family dwellings in Canada. However, continuing occupant complaints of poor acoustic performance in wood-frame buildings that appear to have been built according to wall and floor construction practices recommended in building codes suggest the existence of gaps in current noise control techniques. Forintek initiated this project to investigate the relative importance of noise transmission in wood-frame residential buildings in comparison with other building serviceability issues, and to conduct a pilot study to examine construction designs of wood-frame buildings that exhibit unsatisfactory and satisfactory noise control and to identify existing gaps in current noise control techniques. A literature review and survey of 123 occupants of wood-framed multi- and single-family residential buildings was conducted to determine the relative importance of noise transmission in comparison with other building serviceability attributes. Case studies were conducted on construction details and designs of six new wood-frame condominiums and one single family-house that were built according to code requirements and recommendations for controlling noise transmission. We found that the general public had high expectations regarding adequate acoustic privacy. Even single- family house builders considered low sound transmission important. The multi-family building occupants ranked “sound insulation” the most “important” serviceability attribute, while single-family occupants were most concerned with “water penetration and condensation”. The lowest level of “satisfaction” was given by all respondents to “noise transmission” for their current residences, including single-family occupants, who had ranked it as not being so “important”. The case studies revealed that, current construction practices were much more effective in controlling airborne sound transmission than impact noise. The footfall noise transmission from stairs through the walls is still an unresolved issue that is not considered in the current Canadian Building Code. The low frequency footfall noise transmission between vertically-stacked units was the common complaint in some of these buildings. With no requirement for impact sound insulation in the current National Building Code of Canada, and with our existing knowledge gap concerning low frequency footfall noise transmission problems and solutions to control them, builders, acoustics consultants and design engineers have simply tended to blame wood building materials for noise-related complaints. We concluded that if we are to satisfy the occupants of both single-and multi-family wood-frame buildings and to provide confidence for builders and design engineers in wood-frame construction with satisfactory acoustic performance, a much greater effort is needed to improve sound insulation including development of better sound insulated wood-frame systems and building materials as well as retrofitting techniques. Acoustic performance will be a critical factor for the wood products industry in gaining a greater share of the multi-family construction market and in competing with other building materials.
Acoustic emissions
Documents
Less detail

Hardwood Initiative - Part 5: Development of new processes and technologies in the hardwood industry (Project 16) ; Testing the impacts of tree and stand attributes on the variability of acoustic velocity in standing trees (ST300) and logs (HM200)

https://library.fpinnovations.ca/en/permalink/fpipub5733
Author
Ung, C.-H.
Duchesne, I.
Guo, X.J.
Swift, E.
Date
January 2011
Edition
39324
Material Type
Research report
Field
Sustainable Construction
Author
Ung, C.-H.
Duchesne, I.
Guo, X.J.
Swift, E.
Date
January 2011
Edition
39324
Material Type
Research report
Physical Description
6 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Velocity
Hardwoods
Acoustic
Series Number
Transformative Technologies Program ; Project No. TT5.15
201002825
Location
Québec, Québec
Language
English
Abstract
Hardwood Initiative Project is based on two paradigms. First, the end-use potential and value of a wood product basket can be determined by the properties of its wood and should be quantified as much as possible before trees are harvested. Second, as the correlations between site conditions and wood fibre attributes can be changed by silvicultural treatments, it would be possible to optimize the wood production in terms of quantity and quality through a better understanding of silvicultural impacts on changes in wood fibre properties. This document presents the preliminary results of a research component of the project related to acoustic velocity. It focuses on testing the impacts of tree and stand attributes on the variability of non-destructive velocity (ST300 non-destructive measurement in standing tree) and of destructive velocity (HM200 destructive measurement in log). The acoustic measurements were conducted in 30 plots of sugar maple mixed with yellow birch in New Brunswick. Among the trees measured, 64 trees have been subjected to both non-destructive and destructive velocity measurement. Regression analysis by mixed model showed no significant impact of stand attributes (stand basal area and stand height) on the variation of both velocities. In addition, the defects represented by stem deformation, hole, split, wound, and stump swelling, had no significant impact on both velocities. By cons, the test showed a significant correlation between both velocities and dbh and light crown area of the tree. Non-destructive velocity was better explained by dbh and light crown than the destructive velocity. These results open the potential to produce an equation to predict the non-destructive acoustic velocity of the tree using simple tree attributes (e.g., dbh and light crown) as predictors, and to prescribe the thinning intensity for a desired level of velocity and then a desired level of wood density or stiffness. Full title: Hardwood Initiative - Part 5: Development of new processes and technologies in the hardwood industry (Project 16) : Testing the impacts of tree and stand attributes on the variability of acoustic velocity in standing trees (ST300) and logs (HM200)
Hardwoods
Acoustic velocity
Documents
Less detail

Paramètres ayant une influence sur le fendillement des vernis à l'oxyde d'aluminium

https://library.fpinnovations.ca/en/permalink/fpipub5986
Author
Blanchet, P.
Belleville, B.
Date
July 2005
Edition
42356
Material Type
Research report
Field
Sustainable Construction
Author
Blanchet, P.
Belleville, B.
Date
July 2005
Edition
42356
Material Type
Research report
Physical Description
32 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Flooring
Finishing
Value added
Aluminum
Series Number
General Revenue Report No. 4503
Location
Sainte-Foy, Québec
Language
French
Abstract
L’utilisation massive d’oxyde d’aluminium dans l’industrie des lames de plancher prévernis cause toute sorte de perceptions. Parmi celles-ci, on associe les problèmes de fendillement de surface des lames de plancher à des taux élevés d’oxyde d’aluminium. Un système de finition se bâti de plusieurs couche de polymère et ce n’est généralement que la dernière couche qui comporte la charge inerte. Il est aussi une autre école de penser qui indique que les pratiques de séchage font en sorte que les lames sont vernies à des teneures en humidité inadéquates. En bref, peu de connaissances sur les pratiques de prévernissage sont disponibles. L’objectif de cette étude visait à identifier la ou les sources à l’origine du fendillement dans les lames de plancher de bois franc. Par la même occasion, nous avons tenté de confirmer ou d’infirmer les perceptions populaires quant à l’influence de la teneur en oxyde d’aluminium et de la teneur en humidité du bois lors du vernissage sur le bon comportement du vernis. De plus, l’ensemble de cette démarche offre l’occasion de documenter et de mettre à l’épreuve certaines normes et essais liés au vernis. Les résultats n’ont pas démontré d’effets significatifs du taux d’oxyde d’aluminium ou de la teneur en humidité des lames de plancher sur la résistance à l’impact et sur l’adhérence du vernis. Ce n’est toutefois pas le cas pour l’épaisseur du film, la résistance à l’abrasion, la dureté Pendulum du vernis, la brillance du vernis. Toutes ces propriétés sont influencées par ces paramètres. Au niveau des fentes, les observations mettent en évidence les aspects anatomiques du chêne. En effet, le chêne comporte d’importants rayons ligneux qui se présentent comme une zone de faiblesse dans le plan longitudinal tangentiel. C’est encore plus vrai si les pratiques de séchage ont été sévères. Dans plus de la moitié des fentes observées, du vernis était présent, ce qui confirme que celles-ci étaient présentes lors du vernissage. Ce problème se produit aussi dans d’autres espèces difficiles à sécher telle que le Jatoba.
Finishes - Varnish
Documents
Less detail

Plan a research program for acoustic performance of wood-frame buildings

https://library.fpinnovations.ca/en/permalink/fpipub42066
Author
Hu, Lin J.
Date
March 2001
Material Type
Research report
Field
Sustainable Construction
Author
Hu, Lin J.
Contributor
Canada. Canadian Forest Service
Date
March 2001
Material Type
Research report
Physical Description
9 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Wood frame
Wood
Performance
Acoustic
Series Number
Canadian Forest Service No. 13
E-3581
Location
Sainte-Foy, Québec
Language
English
Abstract
Acoustic performance is one of the important issues that need to be addressed to help wood compete with other materials in the housing market, especially the multi-family housing market. The 1995 National Building Code of Canada (NBCC) increased the minimum sound transmission class (STC) ratings requirement from 45 to 50 between residential suites, and from 50 to 55 between suites and vertical shafts, against the 1990 NBCC. In a recent survey of prefabricated houses, sound performance was reported to be a key concern for increased acceptance of wood-frame buildings components in foreign markets, particularly Europe and Japan, where the code requirements for sound insulation are more stringent than in Canada. In view of this growing awareness of acoustic performance issues in Canada and elsewhere, and the corresponding evolution of building codes, the wood industry needs to demonstrate that wood-frame buildings can match or outperform buildings using other materials with respect to all major criteria, including acoustic performance. This report identifies gaps in the sound-transmission research for wood-frame buildings. These gaps are either issues not completely addressed or understood, or they have been ignored by non-wood researchers or the current National Building Code of Canada. The issues identified include: 1) a lack of design information on Field Sound Transmission Class (FSTC) and Impact Insulation Class (FIIC) ratings for wood-frame construction; 2) conflicts between some construction solutions for sound insulation and other performance attributes; 3) a lack of design and construction guidelines for low frequency thumping noises induced by footsteps in wood-frame construction; 4) limited information on the design of wood-frame construction insulated against exterior noises. Forintek lacks the expertise to deal with noise insulation issues in wood-frame construction. Four potential research projects are proposed to address these issues. It is recommended that Forintek should play an active role in sound insulation research in order to deal with occupant complaints about poor sound performance in wood-frame buildings. Co-ordination with acoustics experts at the Institute for Research in Construction (IRC) and other institutes, the wood and building industries, and code regulators is necessary to the success of any research to be undertaken to fill these gaps, reinforce the performance attributes of Canadian wood-frame systems and increase their market acceptance.