Skip header and navigation

27 records – page 1 of 3.

Advanced wood-based solutions for mid-rise and high-rise construction: acoustic performance of innovative composite wood stud partition walls

https://library.fpinnovations.ca/en/permalink/fpipub49838
Author
Hu, Lin J.
Cuerrier-Auclair, Samuel
Deng, James
Wang, Xiang-Ming
Date
April 2018
Material Type
Research report
Field
Sustainable Construction
Author
Hu, Lin J.
Cuerrier-Auclair, Samuel
Deng, James
Wang, Xiang-Ming
Contributor
Natural Resources Canada. Canadian Forest Service
Date
April 2018
Material Type
Research report
Physical Description
25 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Wood
Vibration
Design
Walls
Studs
Language
English
Abstract
Airborne sound insulation performance of wall assemblies is a critical aspect which is directly associated with the comfort level of the occupants, which in turn affects the market acceptance.
Documents
Less detail

Advanced wood-based solutions for mid-rise and high-rise construction: analytical models for balloon-type CLT shear walls

https://library.fpinnovations.ca/en/permalink/fpipub52680
Author
Chen, Zhiyong
Cuerrier-Auclair, Samuel
Popovski, Marjan
Date
July 2018
Material Type
Research report
Field
Sustainable Construction
Author
Chen, Zhiyong
Cuerrier-Auclair, Samuel
Popovski, Marjan
Contributor
Natural Resources Canada. Canadian Forest Service
Date
July 2018
Material Type
Research report
Physical Description
83 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Building Systems
Subject
Cross Laminated Timber
Performance
Building construction
Building materials
Energy
Language
English
Abstract
Lack of research and design information for the seismic performance of balloon-type CLT shear walls prevents CLT from being used as an acceptable solution to resist seismic loads in balloon-type mass-timber buildings. To quantify the performance of balloon-type CLT structures subjected to lateral loads and create the research background for future code implementation of balloon-type CLT systems in CSA O86 and NBCC, FPInnovations initiated a project to determine the behaviour of balloon-type CLT construction. A series of tests on balloon-type CLT walls and connections used in these walls were conducted. Analytical models were developed based on engineering principles and basic mechanics to predict the deflection and resistance of the balloon-type CLT shear walls. This report covers the work related to development of the analytical models and the tests on balloon-type CLT walls that the models were verified against.
Documents
Less detail

Advanced wood-based solutions for mid-rise and high-rise construction: exit fire separations in mid-rise Wood buildings

https://library.fpinnovations.ca/en/permalink/fpipub49853
Author
Ranger, Lindsay
Dagenais, Christian
Date
March 2018
Material Type
Research report
Field
Sustainable Construction
Author
Ranger, Lindsay
Dagenais, Christian
Contributor
Natural Resources Canada. Canadian Forest Service
Date
March 2018
Material Type
Research report
Physical Description
91 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Wood
Fire
Building code
Residential construction
Language
English
Abstract
In 2015, the National Building Code of Canada (NBCC) [1] adopted prescriptive provisions to allow the construction of mid-rise (5- and 6-storey) buildings using combustible construction. These types of buildings were already permitted under the British Columbia Building Code, as of 2009 [2]. In2014 the Province of Ontario filed an amendment to also allow mid-rise wood buildings, however, it required that the exit fire separations be built using noncombustible construction having a fire resistance rating (FRR) of not less than 1.5-hr, which was an increase from the 1-hr requirement in the NBCC. The Québec Construction Code has also filed amendments to allow mid-rise wood construction and also limits exit stairwells to use noncombustible construction.
Documents
Less detail

Advanced wood-based solutions for mid-rise and high-rise construction: in-situ testing of the arbora building for vibration and acoustic performances

https://library.fpinnovations.ca/en/permalink/fpipub49836
Author
Hu, Lin J.
Cuerrier-Auclair, Samuel
Date
April 2018
Material Type
Research report
Field
Sustainable Construction
Author
Hu, Lin J.
Cuerrier-Auclair, Samuel
Contributor
Natural Resources Canada. Canadian Forest Service
Date
April 2018
Material Type
Research report
Physical Description
40 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Wood
Vibration
Design
Beams
Floors
Language
English
Abstract
This report addresses serviceability issues of tall wood buildings focusing on vibration and sound insulation performance. The sound insulation and vibration performance may not affect building's safety, but affects occupants' comfort and proper operation of the buildings and the funciton of sensitive equipment, consequently the acceptance of midrise and tall wood buildings in market place. Lack of data, knowledge and experience of sound and vibration performance of tall wood buildings is one of the issues related to design and construction of tall wood buildings.
Documents
Less detail

Advanced wood-based solutions for mid-rise and high-rise construction: in-situ testing of the Brock Commons 18-Storey building for vibration and acoustic performances

https://library.fpinnovations.ca/en/permalink/fpipub49837
Author
Hu, Lin J.
Cuerrier-Auclair, Samuel
Date
April 2018
Material Type
Research report
Field
Sustainable Construction
Author
Hu, Lin J.
Cuerrier-Auclair, Samuel
Contributor
Natural Resources Canada. Canadian Forest Service
Date
April 2018
Material Type
Research report
Physical Description
42 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Wood
Vibration
Design
Beams
Floors
Series Number
Transformative Technology ; TT 2018
Language
English
Abstract
This report addresses serviceability issues of tall wood buildings focusing on their vibration and sound insulation performance. The sound insulation and vibration performance may not affect the building’s safety, but affects the occupants’ comfort and the proper operation of the buildings and the function of sensitive equipment, consequently the acceptance of the midrise and tall wood buildings in market place. Lack of data, knowledge and experience of sound and vibration performance of tall wood buildings is one of the issues related to design and construction of tall wood buildings. The measured and estimated values should also be correlated with actual experiences of the occupants in the building if such information is obtained, for example, through a survey.
Documents
Less detail

Advanced wood-based solutions for mid-rise and high-rise construction: in-situ testing of the Origine 13-storey building for vibration and acoustic performances

https://library.fpinnovations.ca/en/permalink/fpipub49852
Author
Hu, Lin J.
Cuerrier-Auclair, Samuel
Date
March 2018
Material Type
Research report
Field
Sustainable Construction
Author
Hu, Lin J.
Cuerrier-Auclair, Samuel
Contributor
Natural Resources Canada. Canadian Forest Service
Date
March 2018
Material Type
Research report
Physical Description
46 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Wood
Vibration
Design
Beams
Floors
Language
English
Abstract
Serviceability performance studied covers three different performance attributes of a building. These attributes are 1) vibration of the whole building structure, 2) vibration of the floor system, typically in regards to motions in a localized area within the entire floor plate, and 3) sound insulation performance of the wall and floor assemblies. Serviceability performance of a building is important as it affects the comfort of its occupants and the functionality of sensitive equipment as well. Many physical factors influence these performances. Designers use various parameters to account for them in their designs and different criteria to manage these performances. Lack of data, knowledge and experience of sound and vibration performance of tall wood buildings is one of the issues related to design and construction of tall wood buildings. survey.
Documents
Less detail

Advanced wood-based solutions for mid-rise and high-rise construction: Mid-rise wood exit shaft demonstration fire test report

https://library.fpinnovations.ca/en/permalink/fpipub49832
Author
Ranger, Lindsay
Dagenais, Christian
Bénichou, Noureddine
Date
April 2018
Material Type
Research report
Field
Sustainable Construction
Author
Ranger, Lindsay
Dagenais, Christian
Bénichou, Noureddine
Contributor
Natural Resources Canada. Canadian Forest Service
Date
April 2018
Material Type
Research report
Physical Description
48 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Wood
Fire
Building code
Residential construction
Language
English
Abstract
FPInnovations conducted a research project to study the construction of mid-rise wood exit shafts in Ontario and Québec. The scope of the project included an investigation into the concerns that have been raised in regards to the use of wood exits in mid-rise buildings, an analysis of recent Canadian fire statistics in residential multi-family structures, and a fire demonstration of a mass timber wall and supported light-frame floor. This report describes the fire demonstration completed as part of this project; this report acts as a supplement to the full project report.
Documents
Less detail

Advanced wood-based solutions for mid-rise and high-rise construction: modelling of timber connections under force and fire

https://library.fpinnovations.ca/en/permalink/fpipub49851
Author
Chen, Zhiyong
Ni, Chun
Dagenais, Christian
Date
March 2018
Material Type
Research report
Field
Sustainable Construction
Author
Chen, Zhiyong
Ni, Chun
Dagenais, Christian
Contributor
Natural Resources Canada. Canadian Forest Service
Date
March 2018
Material Type
Research report
Physical Description
85 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Cross Laminated Timber
Fire
Performance
Timber
Language
English
Abstract
FPInnovations carried out a survey with consultants and researchers on the use of analytical models and software packages related to the analysis and design of mass timber buildings. The responses confirmed that a lack of suitable models and related information for material properties of timber connections, in particular under combination of various types of loads and fire, was creating an impediment to the design and construction of this type of buildings. Furthermore, there is currently a lack of computer models for use in performance-based design for wood buildings, in particular, seismic and fire performance-based design. In this study, a sophisticated constitutive model for wood-based composite material under stress and temperature was developed. This constitutive model was programmed into a user-subroutine and can be added to most general-purpose finite element software. The developed model was used to model the structural performance of a laminated veneer lumber (LVL) beam and a glulam bolted connection under force and/or fire. Compared with the test results, it shows that the developed model was capable of simulating the mechanical behaviour of LVL beam and glulam connection under load and/or fire with fairly good correlation. With this model, it will allow structural designers to obtain the load-displacement curve of timber connections under force, fire or combination of the two. With this, key design parameters such as capacity, stiffness, displacement and ductility, which are required for seismic or fire design, can be obtained. It is recommended that further verification and calibration of the model be conducted on various types of wood products, such as CLT, glulam, SCL and NLT, and fasteners, e.g. screw and rivet. Moreover, a database of the thermal and structural properties of the wood members and fasteners that are commonly used in timber constructions need to be developed to support and facilitate the application of the model.
Documents
Less detail

Advanced wood-based solutions for mid-rise and high-rise construction: proposed vibration-controlled design criterion for supporting beams

https://library.fpinnovations.ca/en/permalink/fpipub49834
Author
Hu, Lin J.
Date
April 2018
Material Type
Research report
Field
Sustainable Construction
Author
Hu, Lin J.
Contributor
Natural Resources Canada. Canadian Forest Service
Date
April 2018
Material Type
Research report
Physical Description
15 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Wood
Vibration
Design
Beams
Floors
Language
English
Abstract
For wood floor systems, their vibration performance is significantly dependent on the conditions of their supports, specifically the rigidity of the support. Detrimental effects could result if the floor supports do not have sufficient rigidity. This is special ture for floor supporting beams. The problem of vibrating floor due to flexible supporting beams can be solved through proper design of the supporting beams. However, there is currently no criterion set for the minimum requirement for floor supporting beam stiffness to ensure the beam is rigid enough. Designers’ current practice is to use the uniform load deflection criteria specified in the code for designing the supporting beams. This criterion is based on certain ratios of the floor span (e.g. L/360, L/480 etc.). The disadvantage of this approach is that it allows larger deflections for longer-span beams than for shorter beams. This means that engineers have to use their experience and judgement to select a proper ratio, particularly for the long-span beams. Therefore, a better vibration-controlled design criterion for supporting beams is needed. It is recommended to further verify the ruggedness of the proposed stiffness criterion for floor supporting beams using new field supporting beam data whenever they become available.
Documents
Less detail

Advanced Wood-based Solutions for Mid-rise and High-rise Construction: Structural Performance of Post-Tensioned CLT Shear Walls with Energy Dissipators

https://library.fpinnovations.ca/en/permalink/fpipub49859
Author
Chen, Zhiyong
Popovski, Marjan
Symons, Paul D.
Date
May 2018
Material Type
Research report
Field
Sustainable Construction
Author
Chen, Zhiyong
Popovski, Marjan
Symons, Paul D.
Contributor
Natural Resources Canada. Canadian Forest Service
Date
May 2018
Material Type
Research report
Physical Description
117 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Cross Laminated Timber
Performance
Building construction
Building materials
Energy
Language
English
Abstract
The latest developments in seismic design philosophy have been geared towards developing of so called "resilient" or "low damage" innovative structural systems that can reduce damage to the structure while offering the same or higher levels of safety to occupants. One such innovative structural system is the Pres-Lam system that is a wood-hybrid system that utilizes post-tensioned (PT) mass timber components in both rigid-frame and wall-based buildings along with various types of energy disspators. To help implement the Pres-Lam system in Canada and the US, information about the system performance made with North American engineered wood products is needed. That information can later be used to develop design guidelines for the designers for wider acceptance of the system by the design community. Several components influence the performance of the Pres-Lam systems: the load-deformation properties of the engineered wood products under compression, load-deformation and energy dissipation properties of the dissipators used, placement of the dissiaptors in the system, and the level of post-tensioning force. The influence of all these components on the performance of Pres-Lam wall systems under gravity and lateral loads was investigated in this research project. The research project consisted on two main parts: material tests and system tests. In the material tests part of the program, a total of 110 compression tests were conducted to determine the load-deformation properties of four different engineered wood products (LVL, LSL, Glulam and CLT) in various directions. The LVL, LSL and Glulam specimens tested under compression parallel to grain had similar linear elastic behaviour with limited ductility. The CLT specimens tested under compression in the major-axis direction had linear elastic behaviour with moderate plasticity. Depending on the type of engineered wood product, typical failure modes included crushing, shear, wedge split and splitting. The compressive strength of the products tested ranged from 42.1 to 53.5 MPa, the global MOE (of the entire specimen under compression) varied between 6390 and 9554 MPa, the local (near the crushing surface) MOE parallel to grain was in the range of 2211 to 5090 MPa, while the local to global MOE ratio ranged from 29.2 to 58.0%, and was higher with the increase in the oven-dry density. The specimens of the four different engineered wood products tested under compression perpendicular to grain or in the minor-axis direction had elastic-plastic behaviour with a clearly defined plastic plateau. Crushing (densification) of the fibres perpendicular to grain was the main failure mode for all specimens, and was in some cases followed by in-plane shear failure or cracking perpendicular to grain. Compression parallel to grain in the middle layer that was followed by its delamination and buckling was a unique failure mode for CLT specimens tested under compression in the minor strength direction. The compressive strength of the engineered wood products tested were in the range of 4.8 to 27.8 MPa, while the global and local MOE perpendicular to grain were in the range of 244 to 2555 MPa, and 320 to 1726 MPa, respectively. The compressive strength and global MOE perpendicular to grain increased with an increase in the oven-dry density. The results show no well-defined trend for the local MOE perpendicular to grain. The specimens loaded in the centre perpendicular to grain had higher strength, global and local MOE than those loaded at the end. A convenient and timesaving design for the axial energy dissipators (fuses) was developed by replacing the epoxy in the original design with two half-tubes. Compared to the original design of fuses with epoxy, the new design with two half-tubes had similar necking failure mode and a longer failure displacment, thus providing user-friendly fuses that performed similar or even better than the original design. In the system tests part of the program, a total of 17 different PT and Pres-Lam CLT walls with six different configurations were tested under monotonic and reversed cyclic loading. The studied parameters included the level of PT force, the position of the fuses, and the number of UFPs. CLT shear walls subjected only to post-tensioning, had non-linear elastic behaviour. The behaviour of the PT walls with and without energy dissipators was relatively similar under monotonic and cyclic loading. The strength degradation observed during the cyclic tests was low in all wall configurations suggesting that very little damage was inflicted upon the structure during the first cycles at any deformation level. Four major failure modes, including yielding and buckling of fuse, crushing and splitting of wood at the end of wall, and buckling of lumber in the exterior-layer of CLT wall, were observed in the tests. The yielding in fuses occurred at the early stage of loading as designed and the other failure modes happened when the lateral drift reached or beyond 2.5%. The initial stiffness of the single-panel PT CLT walls tested ranged from 1.80 to 2.31 kN/mm, the load at the decompression point and 2.5% drift were in the range of 4.2 to 14.9 kN and 32.7 to 45.9 kN, respectively. The initial stiffness of the single-panel Pres-Lam CLT walls tested ranged from 1.69 to 2.44 kN/mm, the load at the decompression point and 2.5% drift were in the range of 21.0 to 30.2 kN and 59.6 to 69.8 kN, respectively. All the mechanical properties increased with an increase in the PT force. The average initial stiffness and the load at 2.5% drift of the coupled-panel Pres-Lam CLT walls tested were 4.59 kN/mm and 151.3 kN, respectively, while the load at the decompression point increased from 58.4 to 69.7 kN by increasing the number of UFP. The test results show that the behaviour of the Pre-Lam CLT shear walls can be de-coupled and a “superposition rule” can be applied to obtain the stiffness and resistance of such system. The test results gave a valuable insight into the structural behaviour of the PT and Pres-Lam CLT shear wall under in-plane lateral loads. The data from the testing will be used in the future for development of numerical computer models. They will also be used for development of design guidelines for this system. All tests conducted in this study and the analyses in the future modelling research will form the basis for developing future design guidelines for PT and Pres-Lam mass timber systems.
Documents
Less detail

27 records – page 1 of 3.