Skip header and navigation

5 records – page 1 of 1.

Comportement au feu des bâtiments en CLT

https://library.fpinnovations.ca/en/permalink/fpipub42938
Author
Craft, S.T.
Date
January 2011
Material Type
Research report
Field
Sustainable Construction
examinateurs Andrew Harmsworth, P.Eng., GHL Consultants LTD Jim Mehaffey, Ph. D., Fire Science Applications
Author
Craft, S.T.
Date
January 2011
Material Type
Research report
Physical Description
38 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Building Systems
Subject
Timber
Laminate product
Building construction
Design
Fire
Language
French
Abstract
Les panneaux en bois lamellé-croisé (CLT) peuvent offrir une excellente résistance au feu, souvent comparable à celle des constructions lourdes typiques non combustibles. En raison de la nature inhérente des pièces en gros bois d’oeuvre à carboniser lentement et à un taux prévisible, les systèmes en bois massif peuvent maintenir une capacité structurale significative pour des durées prolongées lorsque exposés au feu. Afin de faciliter l’acceptation de futures dispositions du code pour la conception des panneaux de CLT résistant au feu, un projet de recherche d’un an a été lancé chez FPInnovations en avril 2010. L’objectif principal du projet était de développer et de valider une procédure générique pour calculer les caractéristiques de résistance au feu des assemblages de mur et de plancher de CLT. Une série d’essais de comportement au feu en vrai grandeur est en cours pour comparer le degré de résistance au feu mesuré lors de tests standards à celui calculé en utilisant la procédure proposée. Compte tenu du fait que le projet de recherche en est à ses débuts (lors de la rédaction de ce chapitre), une procédure de conception simple, mais conservatrice, est présentée dans ce chapitre, selon l’information de pointe provenant de l’Europe et de l’Amérique du Nord. La norme canadienne sur les règles de calcul des charpentes en bois (CSA O86) peut être employée pour calculer le degré de résistance au feu des panneaux de CLT avec la même méthodologie qui est actuellement employée pour calculer les degrés de résistance au feu du bois de construction lamellé-collé et du gros bois d’oeuvre aux États-Unis, en Nouvelle-Zélande et en Europe. Cette méthode est connue sous le nom de « méthode de la section résiduelle ou efficace » et permet l’utilisation des valeurs de calcul que l’on retrouve dans la norme CSA O86. On recommande de faire appel à un ingénieur qualifié en protection contre les incendies pour diriger ou surveiller la conception des assemblages de CLT afin d’obtenir le degré de résistance au feu désiré. L’ingénieur en protection contre les incendies devrait travailler étroitement avec l’ingénieur en structure afin de bien évaluer les effets de l’exposition au feu sur la structure.
Documents
Less detail

Fire modelling : full-scale test of a localized fire in houses. Part 1 : Reviewed NRC commission tests

https://library.fpinnovations.ca/en/permalink/fpipub39430
Author
Lu, Ling
Date
January 2011
Material Type
Research report
Field
Sustainable Construction
Author
Lu, Ling
Date
January 2011
Material Type
Research report
Physical Description
15 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Building Systems
Subject
Fire
Building construction
Residential construction
Series Number
Project No. CFS 3.22
Transformative Technologies Program
E-4782
Location
Ottawa, Ontario
Language
English
Abstract
Fire Modelling
Full-scale tests
Documents
Less detail

Fire modelling : full-scale test of a localized fire in houses. Part 2 : Test set up

https://library.fpinnovations.ca/en/permalink/fpipub39431
Author
Lu, Ling
Date
January 2011
Material Type
Research report
Field
Sustainable Construction
Author
Lu, Ling
Date
January 2011
Material Type
Research report
Physical Description
16 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Building Systems
Subject
Fire
Building construction
Residential construction
Series Number
Project No. CFS 3.22
Transformative Technologies Program
E-4783
Location
Ottawa, Ontario
Language
English
Abstract
Fire Modelling
Full-scale tests
Documents
Less detail

Foam fire-suppression system for mobile forestry equipment

https://library.fpinnovations.ca/en/permalink/fpipub39938
Author
Macey, T.
Date
December 1991
Material Type
Research report
Field
Fibre Supply
Author
Macey, T.
Date
December 1991
Material Type
Research report
Physical Description
4 p.
Sector
Forest Operations
Field
Fibre Supply
Research Area
Forestry
Subject
Fire
Safety
Equipment
Forestry
Series Number
Technical Note Wood Harvesting ; TN 175
Language
English
Abstract
CABLE LOGGING
CABLES
Cable life
INSPECTION SYSTEM
ELECTROMEGNETIC WIRE ROPE INSPECTION (EWRI)
Prototype
Documents
Less detail

Modelling of dimension lumber in axial compression at elevated temperatures

https://library.fpinnovations.ca/en/permalink/fpipub42020
Author
Van Zeeland, I.
Date
February 2001
Material Type
Research report
Field
Sustainable Construction
Author
Van Zeeland, I.
Contributor
Canada. Canadian Forest Service
Date
February 2001
Material Type
Research report
Physical Description
68 p.
Sector
Wood Products
Field
Sustainable Construction
Research Area
Advanced Wood Materials
Subject
Mechanical properties
Fire
Series Number
Canadian Forest Service No. 9
E-3524
Location
Sainte-Foy, Québec
Language
English
Abstract
The design of wood-frame structural systems to withstand exposure to fire depends on knowledge of the fire endurance (time-to-failure) of the wood members used in the system. In fires, wood looses part of its load-carrying capacity due to charring and part due to strength degradation. This thesis examines the reduction in compression strength experienced by dimension lumber when exposed to elevated temperatures. A program of experimental testing of nominal 2×4 Machine Stress Rated (MSR) lodgepole pine lumber concentrically loaded in compression and exposed to elevated temperature was undertaken by Forintek Canada Corp., Canada's wood products research institute. A computer program entitled HTExposure was written to simulate the experimental time-to-failure data gathered in Forintek's testing program. This computer program combines a modification of an existing heat-transfer model with various published compression-strength reduction models. This was done in order to determine which of those strength-reduction models could predict times-to-failure comparable to the observed values. As well, a new compression-strength reduction model was proposed. When predicted results were compared to the observed data, it was determined that the computer program predicted results closest to those observed when using the new compression-strength reduction model proposed in this study.
Lumber modelling
Axial compression
Elevated temperatures
Documents
Less detail